Showroom

Showroom
Showroom

Thursday, December 24, 2015

What 's Electromagnetic flow meter ?

Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.   
Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.
Besides measuring flow of general conductive liquid electromagnetic flowmeter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.

Smart electromagnetic flow meters consist of sensor and smart signal transducer. And it can be classified into two structures--- integral type and remote type according to the set-up form of the sensor and transducer. In terms of integral type electromagnetic flow meters, transducer and sensor directly assembles as a whole and can not be dissociated. It is usually used at the scene where the environmental situation is good. To remote type electromagnetic flow meters transducer composes a product through a special electric cable and sensor. The sensor is installed at the scene and the transducer is installed in the place where the conditions are good. It is usually used at the scene where the environmental situation is poor, such as underground wells, high temperature and the place where people can not reach. 

Merry Christmas And Happy New Year


New year is coming , BCST Group wish all of our cilents  a love filled Christmas and New Year .
May your Christmas be filled with special moment , warmth, peace and happiness , the joy of covered ones nears and wishing you all the joy of Chrsimas and a year of happiness .  
                                                                                                                                                                ---------BCST Group 

Friday, November 6, 2015

EJC Series Pressure transmitter & Differential Pressure transmitter









Features 
  High accuracy
  No mechanical and movable parts, little repair work
  Span and zero continuous and adjustable from outside
  Good stability
  Positive shift amount to 500%; negative shift 600%
  Two-wire system 4~20mA DC
  Damping adjustable, overpressure protection
  Solid components, patch-type printed circuit board
  Explosion-proof structure, all-day use
  Unified structure, strong interchangeability of parts
  Miniaturizationtotal height 166mm
  Diaphragm materials of contacting mediums option (316L, TAN, HAS-C, MONEL, etc.)
  smart HART protocol 

Function Parameters 


 Service: liquid, gas and steam
 Measuring range : 0~0.06 kPa to 0~40Mpa
 Output signal : 4~20mA DC (four-wire 220V AC power supply, 0~10mA DC output for special)
 Power supply : 12~45V DC, generally 24V DC
 Features of loading: relation equation of loading impedance RL and power voltage 
           Vs: RL <= 50(Vs-12)
 Indicator : pointer-type linearity indication 0~100% scale mark or LCD indicator, LED indicator.
 Explosion proof : a. explosion isolation  d II CT6
              b. intrinsically safe ia II CT6
 Positive and negative shifts : after positive and negative shifts of zero absolute values of upper-and-lower-limit values of span and measuring range not exceed 100% of upper limit of measuring range.( smart type : turn down ratio 20:1, 40:1
Maximum positive shift is 500% of minimum adjusting span; maximum negative shift is 600% of minimum adjusting span.
 Temperature range: amplifier operation temperature range: -29 ~ +93C
 (LT type: -25 ~ +70C); measuring component of fill silicone oil: -40 ~ +104C
 flange type transmitter fill hi-temperature silicone oil: -20 ~ +315C normal silicone oil: -40 ~ 

  +149C
 Static pressure : 4, 10, 25, 32Mpa
 Humidity : relative humidity 0~100%
  Volume absorption : < 0.16cm3
     Damping (phase step response) : For silicone oil, generally between 0.2s and1.67s, continuous and adjustable

JC-090 Electromagnetic Flow meter

Description Of Products 

Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.   
Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.
Besides measuring flow of general conductive liquid electromagnetic flowmeter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.

PERFORMANCES & FEATURES
 Simple structures, firm, no movable parts and long operation life
 No intercepting fluid parts, no pressure loss and fluid clogging
 No mechanical inertia, quick response and good stability, apply in automatic examination, adjustment and controlling 
 Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.
 Employ Teflon or rubber liner and different combination of electrode material such as Hastelloy C, Hastelloy B, 316L, 
 T itanium and adapt the need of different mediums.
 Supply many styles of flowmeters such as inline type and insertion type, etc.
 Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.
 Integral type flowmeters and remote type flowmeters.
 LCD back light display with high clearness

Technical Data 
                                                                              Sheet 1 
Suitable Diameter
DN25~DN2600 (below DN25 non-standard,which should be customized)
Electrodes Materials
316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum
Suitable Fluid
Liquid with conductive ratio more than 5 μs/cm
Measuring Range
0.1~10m/s (extendable to 15m/s)
Upper Limit of Span
0.5~10m/s. 1~5m/s recommended
Accuracy 
0.3%, 0.5%,1.0%
Output Signals
4~20mADC, load<= 750ohm, 0~3kHz, 5V with source and changeable width. 
high terminal and effective frequency output , RS485 interface
Operation Pressure
1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special) 
Fluid Temperature
-20C~80C, 80C~130C,130C~180C Depending on Lining Material
Ambient Temperature
Sensor -40C~80C. transducer -15C~50C
Ambient Humidity
<= 85%RH (at 20C)
Cable Outlet Size
M20×1.5
Power Supply
220VAC±10%, 50Hz±1Hz, 24VDC±10%
Power Consumption
<=8W
Protection Ratings
Integral type: IP65. remote type: sensor IP68,transducer IP65
Materials of Liner
PTFE, soft rubber, hard rubber, PFA, etc
Connection of Flange
National Standard GB9119-88(DIN2051,BS4504)
Earthing Materials
316L (stainless steel), HC, Ti, Ta, Cu
 Model Selection 
1. Model Selection                                                    Sheet 2   
Code
Nominal Diameter 
(mm)
Flow Range
(m3/h)
Code
Nominal Diameter (mm)
Flow Range 
(m3/h)
JC-090-15
JC-090-20
JC-090-25
JC-090-32
JC-090-40
JC-090-50
JC-090-65  JC-090-80
JC-090-100
JC-090-125
JC-090-150
JC-090-200
JC-090-250
JC-090-300
JC-090-350
JC-090-400
DN15
DN20
DN25
DN32
DN40
DN50
DN65
DN80
DN100
DN125
DN150
DN200
DN250
DN300
DN350
DN400
0.19~6.36
0.34~11.3
0.53~17.66
0.87~28.94
1.36~45.22
2.12~70.65
3.58~119.40
5.43~180.86
8.48~282.6
13.25~441.56
19.08~635.85
33.91~1130.40
52.99~1766.25
76.30~2543.40
103.86~3461.85
135.65~4521.60
JC-090-450
JC-090-500
JC-090-600
JC-090-700
JC-090-800
JC-090-900
JC-090-1000 
JC-090-1200
JC-090-1400
JC-090-1600
JC-090-1800
JC-090-2000
JC-090-2200
JC-090-2400
JC-090-2600
DN-450
DN-500
DN-600
DN-700
DN-800
DN-900
DN-1000 
DN-1200
DN-1400
DN-1600
DN-1800
DN-2000
DN-2200
DN-2400
DN-2600
171.00~5722.65
211.95~7065.00
305.21~10173.00
415.42~13847.40
542.59~18086.40
686.72~22890.60
847.80~28260.00
1220.83~40694.40
1661.69~55389.60
2170.37~72345.60
2746.87.00~91562.40
3391.20~113040.00
4103.35~136778.40
4883.33~162777.60
5731.13~191037.60
Code
Electrode Material
K1
K2
K3
K4
K5
K6
K7
SS 316L 
Hastelloy B
Hastelloy C
Titanium 
Tantalum 
Pt/Iridium Alloy
Stainless Steel Painting Tungsten Carbide

Code 
Material of liner

C1
C2
C3
C4
C5
C6
C7
PTFE (F4 or Teflon)
Fluorinated Ethylene Propylene (FEP)
Fs
PO (Soft Rubber)
Polyurethane Rubber (PUR)
Hard Rubber
PFA
Code
Function
E1
E2
E3
F1
F2

F3
F4
T1
T2
T3
P1
P2
P3
P4
P0
D1
D2
D3
J1
J2
J3
Class 0.3%
Class 0.5%
Class 1.0%
4~20mADC, load ≤750Ω
0~3kHz, 5V active, changeable pulse, high-terminal and effective frequency output
RS 485 interface (Modbus)
HART
Normal Temperature 
High Temperature 
Ultra Temperature 
1.0MPa
1.6MPa
4.0MPa
16MPa
Special Pressure
220VAC+10%; 50Hz1Hz
24VDC+10%
Battery Operated
Integral Type 
Remote Type 
Explosion-proof, Integral 
EN
English