EJC Series Pressure transmitter & Differential Pressure transmitter
Features
● High accuracy
● No mechanical and movable parts, little repair work
● Span and zero continuous and adjustable from outside
● Good stability
● Positive shift amount to 500%; negative shift 600%
● Two-wire system 4~20mA DC
● Damping adjustable, overpressure protection
● Solid components, patch-type printed circuit board
● Explosion-proof structure, all-day use
● Unified structure, strong interchangeability of parts
● Miniaturization(total height 166mm)
● Diaphragm materials of contacting mediums option (316L, TAN, HAS-C, MONEL, etc.)
● smart HART protocol
Function Parameters
● Service: liquid, gas and steam
● Measuring range : 0~0.06 kPa to 0~40Mpa
● Output signal : 4~20mA DC (four-wire 220V AC power supply, 0~10mA DC output for special)
● Power supply : 12~45V DC, generally 24V DC
● Features of loading: relation equation of loading impedance RL and power voltage
Vs: RL <= 50(Vs-12)
● Indicator : pointer-type linearity indication 0~100% scale mark or LCD indicator, LED indicator.
● Explosion proof : a. explosion isolation d II CT6
b. intrinsically safe ia II CT6
● Positive and negative shifts : after positive and negative shifts of zero absolute values of upper-and-lower-limit values of span and measuring range not exceed 100% of upper limit of measuring range.( smart type : turn down ratio 20:1, 40:1)
Maximum positive shift is 500% of minimum adjusting span; maximum negative shift is 600% of minimum adjusting span.
● Temperature range: amplifier operation temperature range: -29 ~ +93C
(LT type: -25 ~ +70C); measuring component of fill silicone oil: -40 ~ +104C
flange type transmitter fill hi-temperature silicone oil: -20 ~ +315C normal silicone oil: -40 ~
+149C
● Static pressure : 4, 10, 25, 32Mpa
● Humidity : relative humidity 0~100%
● Volume absorption : < 0.16cm3
● Damping (phase step response) : For silicone oil, generally between 0.2s and1.67s, continuous and adjustable
JC-090 Electromagnetic Flow meter
Description Of Products
Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.
Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.
Besides measuring flow of general conductive liquid electromagnetic flowmeter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.
PERFORMANCES & FEATURES
● Simple structures, firm, no movable parts and long operation life
● No intercepting fluid parts, no pressure loss and fluid clogging
● No mechanical inertia, quick response and good stability, apply in automatic examination, adjustment and controlling
● Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.
● Employ Teflon or rubber liner and different combination of electrode material such as Hastelloy C, Hastelloy B, 316L,
● T itanium and adapt the need of different mediums.
● Supply many styles of flowmeters such as inline type and insertion type, etc.
● Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.
● Integral type flowmeters and remote type flowmeters.
● LCD back light display with high clearness
Technical Data
Sheet 1
Suitable Diameter
|
DN25~DN2600 (below DN25 non-standard,which should be customized)
|
Electrodes Materials
|
316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum
|
Suitable Fluid
|
Liquid with conductive ratio more than 5 μs/cm
|
Measuring Range
|
0.1~10m/s (extendable to 15m/s)
|
Upper Limit of Span
|
0.5~10m/s. 1~5m/s recommended
|
Accuracy
|
0.3%, 0.5%,1.0%
|
Output Signals
|
4~20mADC, load<= 750ohm, 0~3kHz, 5V with source and changeable width.
high terminal and effective frequency output , RS485 interface
|
Operation Pressure
|
1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special)
|
Fluid Temperature
|
-20C~80C, 80C~130C,130C~180C Depending on Lining Material
|
Ambient Temperature
|
Sensor -40C~80C. transducer -15C~50C
|
Ambient Humidity
|
<= 85%RH (at 20C)
|
Cable Outlet Size
|
M20×1.5
|
Power Supply
|
220VAC±10%, 50Hz±1Hz, 24VDC±10%
|
Power Consumption
|
<=8W
|
Protection Ratings
|
Integral type: IP65. remote type: sensor IP68,transducer IP65
|
Materials of Liner
|
PTFE, soft rubber, hard rubber, PFA, etc
|
Connection of Flange
|
National Standard GB9119-88(DIN2051,BS4504)
|
Earthing Materials
|
316L (stainless steel), HC, Ti, Ta, Cu
|
Model Selection
1. Model Selection Sheet 2
Code
|
Nominal Diameter
(mm)
|
Flow Range
(m3/h)
|
Code
|
Nominal Diameter (mm)
|
Flow Range
(m3/h)
| |
JC-090-15
JC-090-20
JC-090-25
JC-090-32
JC-090-40
JC-090-50
JC-090-65 JC-090-80
JC-090-100
JC-090-125
JC-090-150
JC-090-200
JC-090-250
JC-090-300
JC-090-350
JC-090-400
|
DN15
DN20
DN25
DN32
DN40
DN50
DN65
DN80
DN100
DN125
DN150
DN200
DN250
DN300
DN350
DN400
|
0.19~6.36
0.34~11.3
0.53~17.66
0.87~28.94
1.36~45.22
2.12~70.65
3.58~119.40
5.43~180.86
8.48~282.6
13.25~441.56
19.08~635.85
33.91~1130.40
52.99~1766.25
76.30~2543.40
103.86~3461.85
135.65~4521.60
|
JC-090-450
JC-090-500
JC-090-600
JC-090-700
JC-090-800
JC-090-900
JC-090-1000
JC-090-1200
JC-090-1400
JC-090-1600
JC-090-1800
JC-090-2000
JC-090-2200
JC-090-2400
JC-090-2600
|
DN-450
DN-500
DN-600
DN-700
DN-800
DN-900
DN-1000
DN-1200
DN-1400
DN-1600
DN-1800
DN-2000
DN-2200
DN-2400
DN-2600
|
171.00~5722.65
211.95~7065.00
305.21~10173.00
415.42~13847.40
542.59~18086.40
686.72~22890.60
847.80~28260.00
1220.83~40694.40
1661.69~55389.60
2170.37~72345.60
2746.87.00~91562.40
3391.20~113040.00
4103.35~136778.40
4883.33~162777.60
5731.13~191037.60
| |
Code
|
Electrode Material
| |||||
K1
K2
K3
K4
K5
K6
K7
|
SS 316L
Hastelloy B
Hastelloy C
Titanium
Tantalum
Pt/Iridium Alloy
Stainless Steel Painting Tungsten Carbide
| |||||
Code
|
Material of liner
| |||||
C1
C2
C3
C4
C5
C6
C7
|
PTFE (F4 or Teflon)
Fluorinated Ethylene Propylene (FEP)
Fs
PO (Soft Rubber)
Polyurethane Rubber (PUR)
Hard Rubber
PFA
| |||||
Code
|
Function
| |||||
E1
E2
E3
F1
F2
F3
F4
T1
T2
T3
P1
P2
P3
P4
P0
D1
D2
D3
J1
J2
J3
|
Class 0.3%
Class 0.5%
Class 1.0%
4~20mADC, load ≤750Ω
0~3kHz, 5V active, changeable pulse, high-terminal and effective frequency output
RS 485 interface (Modbus)
HART
Normal Temperature
High Temperature
Ultra Temperature
1.0MPa
1.6MPa
4.0MPa
16MPa
Special Pressure
220VAC+10%; 50Hz+ 1Hz
24VDC+10%
Battery Operated
Integral Type
Remote Type
Explosion-proof, Integral
| |||||
EN
|
English
|
Subscribe to: