Cases for Wrong Installation of Electromagnetic Flowmeter
Case 1: The Flow Value Jitters Seriously.
Analysis: There is pump tightly closed to the flow meter on the spot. When the liquid flows through the flow meter, it will be in the turbulent condition,
which exists strong interference in measurement. That is why the value of flow meter always jitters.
Solution: Be far away from the pump and choose the straight pipe distance, at least five times of pipe diameter longer, to guarantee the flow steady.
As below is the similar case that is installed closed to valves.
Case 2: The Measurement Is Always Not Correct. Sometimes ATC Alarm And Lower Limit Alarm Will Occur Sometimes.
Analysis: From the picture above, there is half pipe of water inside, which means it isn’t full pipe measurement for electromagnetic flow meters.
That is why its measurement is not correct.
Solution: reduce and extend the pipe, let the liquid fulfill the pipe.
Case 3: The Electromagnetic Flow Meters Always Damage.
Analysis: If installed in the places where there is water immersion risk, the flow meters have to be IP68.
Solution: choose IP68
Why is the installation of electromagnetic flow meters so strict?
In which conditions will guarantee the liquid is fulfilled in the pipe?
It is surely full pipe in the vertical pipe. It is also full pipe in the horizontal pipe if installed correctly.
and let the liquid go through the flow meters uniformly and steadily. (5 times of pipe diameter longer upstream and 5 times of pipe diameter longer downstream)
Analysis: There is pump tightly closed to the flow meter on the spot. When the liquid flows through the flow meter, it will be in the turbulent condition,
which exists strong interference in measurement. That is why the value of flow meter always jitters.
Solution: Be far away from the pump and choose the straight pipe distance, at least five times of pipe diameter longer, to guarantee the flow steady.
As below is the similar case that is installed closed to valves.
Case 2: The Measurement Is Always Not Correct. Sometimes ATC Alarm And Lower Limit Alarm Will Occur Sometimes.
Analysis: From the picture above, there is half pipe of water inside, which means it isn’t full pipe measurement for electromagnetic flow meters.
That is why its measurement is not correct.
Solution: reduce and extend the pipe, let the liquid fulfill the pipe.
Case 3: The Electromagnetic Flow Meters Always Damage.
Analysis: If installed in the places where there is water immersion risk, the flow meters have to be IP68.
Solution: choose IP68
Why is the installation of electromagnetic flow meters so strict?
- The measurement principle of electromagnetic flow meters is based on Faraday induction, conducting medium’s cutting magnetic line generates inductive emf,
- and the signal is collected by the electrodes in the central axis.
In which conditions will guarantee the liquid is fulfilled in the pipe?
It is surely full pipe in the vertical pipe. It is also full pipe in the horizontal pipe if installed correctly.
- The flow velocity of liquid through the pipe has to be uniform and stable. Why? The flow measurement is actually the product value of velocity and pipe CSA.
- Then if velocity is not steady, the flow measurement will jitter.
and let the liquid go through the flow meters uniformly and steadily. (5 times of pipe diameter longer upstream and 5 times of pipe diameter longer downstream)
Thursday, June 29, 2017
Tuesday, June 13, 2017
High accuracy pressure sensor -silicon resistive pressure sensor
Our pressure sensor production has successfully launched in 2016 , and in the past year , our sensor has tested well and stable . The best accuracy can reach 0.05%, the standard accuracy is 0.075% . The stability and repeatibility have improved a lot comparing to capacitance type sensor . Currently , we have sold to Iran , Russia , South Korean . Welcome to contact us .
our website:www.bcstgroup.com ,info@bcstgroup.com
Thursday, May 25, 2017
Silicone Resonant Pressure Sensor Manufacturer,www.bcstgroup.com
Silicone Resonant Pressure Sensor Manufacturer
http://www.icontact-archive. com/ bWoWyIETXH3NkpeojwXQIYbX2paYSW zJ
http://www.icontact-archive.
Thursday, May 18, 2017
Friday, May 12, 2017
Thursday, May 11, 2017
Wednesday, May 3, 2017
Pressure transmitter Technology from Germany for silicon resonant sensor
Cooperation with Muesan about Pressure Sensor Technology
BCST has purchased the 0.075% silicon resonant pressure sensor technology and equipment from Germany
|
Dated 30th,April , in Frankfurt ,Germany . BCST has signed the contract with Muesen company
Muesen Technik GmbH is specialized in the technology for sensor , especially for pressure sensor .
|
BCST is a professional manufacturer in China for pressure transmitter . It has win good reputation in various industry in China .
The cooperation will update Chinese pressure transmitter technology , and improve our product quality .
Chinese Local Governers from Jinhu attend this important meeting .
The government plan to make BCST become the most advanced pressure transmitter manufacturer in China
|
Subscribe to:
Posts (Atom)