Showroom

Showroom
Showroom

Sunday, May 31, 2020

Integral v-cone flow transmitter

Integral v-cone flow transmitter
V-cone flowmeter is widely used in petroleum, chemical industry, natural gas, mining and metallurgy, steel, electric power, water, water supply and drainage, paper making, sugar processing, pharmaceutical, brewing, beverage, textile, printing, dyeing, chemical fiber, environmental protection and municipal engineering industry measurement.
Because of the unique structure of V-cone flowmeter, fluid in the pipe doesn’t sharply contract, the change of fluid pressure is stable, and differential pressure signal is more stable, to ensure accurate measurement of flow, especially small flow.
At the same time, because of suspension of axis and tapered body structure, when fluid close to V cone, pipe center velocity slows while velocity around pipe wall speeds. High speed fluid directly washes inner cone throttling element and pipe wall, automatically realize cleaning, to avoid adhesion and accumulation of smudgy medium. It is applicable for liquid containing gas, gas containing water and gas or liquid containing solid. It has a unique advantage in measurement of coke oven gas, blast furnace gas, natural gas, liquefied petroleum gas, high-viscosity crude oil and smudgy.  
BCST V-cone flowmeter is widely used in petroleum, chemical industry, natural gas, mining and metallurgy, steel, electric power, water, water supply and drainage, paper making, sugar processing, pharmaceutical, brewing, beverage, textile, printing, dyeing, chemical fiber, environmental protection and municipal engineering industry measurement.
If you want to know more detailed information about this product, you can click the link below:
Adopt National standard: GB/T2624-1993, SY / T6143-2004, International standard ISO5167
Pipe size: DN15 – DN3000
Basic Error: ±0.5%, ±1.5%, ±2.5%
Repeatability: ±0.1%
Working pressure: 2.5 MPa, 4.0MPa, 6.3 MPa, 10.0 MPa, 16.0 MPa, 26.0 MPa, 42.0 MPa
Medium temperature: < 550 ℃ 
Medium: Liquid, gas (including natural gas) or steam
Turndown: 10:1
Requirements to straight tube section: upstream 0-3D, downstream 0-1D
Power supply: 1) external: 24V DC  2) Internal (built-in battery): 3.6V DC
Display: 8-digit LCD display of flow rate, totalizer, flux pressure, flux temperature & troubleshot code.
Output signal: 1) 4-20mA DC flow signal
               2) Fit output signal of HRT protocol
               3) No output signal for battery powered flow meter  
Explosion proof: Intrinsically safe type IbIICT5
Enclosure: IP65 
Nominal Diameter
L (mm)
C
Nominal Diameter
L (mm)
C
DN15
150
M12 ×1.25
DN250
650
M20 ×1.5
DN20
150
M12 ×1.25
DN300
700
M20 ×1.5
DN25
150
M12 ×1.25
DN350
900
M20 ×1.5
DN32
165
M12 ×1.25
DN400
1050
M20 ×1.5
DN40
200
M12 ×1.25
DN450
1150
M20 ×1.5
DN50
250
M20 ×1.5
DN500
1260
M20 ×1.5
DN65
275
M20 ×1.5
DN600
1380
M20 ×1.5
DN80
300
M20 ×1.5
DN700
1500
M20 ×1.5
DN100
350
M20 ×1.5
DN800
1600
M20 ×1.5
DN125
400
M20 ×1.5
DN900
1750
M20 ×1.5
DN150
450
M20 ×1.5
DN1000
1850
M20 ×1.5
DN175
500
M20 ×1.5
DN1200
2000
M20 ×1.5
DN200
550
M20 ×1.5
DN1400
2200
M20 ×1.5
DN225
600
M20 ×1.5
DN1600
2500
M20 ×1.5
If you want to know more products of our company, please click here

Thursday, May 28, 2020

Pneumatic Tri-Eccentric Hard Seal Butterfly Valve Delivery

The disc of the tri-eccentric hard seal butterfly valve is installed in the diameter direction of the pipeline. In the butterfly valve body cylindrical channel, disc shaped disc around the axis of rotation, rotation Angle between 0°~90°, rotation to 90°, the valve is fully open. The characteristics of the new high life stainless steel butterfly valve and the problems in the use of the butterfly valve.
The tri-eccentric hard seal butterfly valve is widely used in metallurgy, electric power, petrochemical industry, water supply and drainage, municipal construction and other industrial pipelines where the medium temperature is no more than 425℃, for regulating the flow and cutting off the fluid.
 big-size-pneumatic-butterfly-valve
Pneumatic tri-eccentric hard seal butterfly valve is based on the two -eccentric hard seal butterfly valve to generate an angle (the sealing surface is an inclined cone), thus forming the tri-eccentric hard seal butterfly valve . The structure has no mechanical wear and scratch in the process of opening and closing , small closing torque , good cutting performance and long service lige , as well as two functions of adjustment and cutting.
This Pneumatic tri-eccentric hard seal butterfly valve is DN800 , for air application , its function for cut-off air course.   It is for one chemical industry in Southeast of China.   
The valve body is WCB , pressure is DIN 0.6 Mpa , working temperature is -60 to 200 °C  
The max size for  Pneumatic tri-eccentric hard seal butterfly valve BCST can make is DN 2000.
If you have any special requirement , we can also make based on your detail.  
pneumatic-trieccentric-butterfly-valve


Tuesday, May 19, 2020

JCWQ Turbine Gas Flow Meter 


JCWQ series gas turbine flowmeter is widely used for measurement of natural gas, coal gas, liquefied gas and light hydrocarbon gas, etc. 
Feature 
■ Dedicated instrument for gas measurement
■ Dedicated instrument for oil & gas recycle system
■ High accuracy: ±1.5%, ±1.0% or ±0.75%
■ Good repetitiveness
■ Test temperature, pressure and flow of measured gas; automatic tracking and compensation of flow; indication of gas total volume under standard status; real-time query of temperature, pressure, time and date, etc.
■ Built-in pressure & temperature sensor, high safety performance, compact structure & beautiful outlook
■ Low power consumption, more than 3 years service life for one 3V 10AH lithium cell
■ Instrument factor, total flow value kept for 10 years after power off
Technical Parameter for BCST Turbine Gas Flow Meter 
DN (mm) & Connection
25, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300 flange connection
25, 40 thread connection
Accuracy
±1.5%, ±1.0% or ±0.75% (need special order)
Turndown
1:10; 1:20; 1:30
Instrument Material
Body: 304 SS; impeller: anti-corrosive ABS or high-quality aluminum alloy; indicator: cast aluminum
Medium Temperature (℃)
-30 ℃ ~ +80 ℃
Ambient Conditions
Temperature: -20℃~+60℃, relative humidity 5% ~ 90%, atmospheric pressure 86 ~ 106 KPa
Output Signal
Sensor: pulse frequency signal, low level less than 0.8V, high level more than 8V
Transmitter: two wire 4-20mA DC current signal
Power Supply
Sensor: +12V DC, +24V DC (optional)
Transmitter: +24V DC
Local indication type: built-in 3V lithium cell
Signal Transmission Line
STVPV3×0.3 (3 wire), 2×0.3 (2 wire)
Transmission Distance
No more than 1000 m
Signal Line Interface
M20×1.5(F)
Explosion Proof
ExdIIBT6
Enclosure Protection
IP65

If you want to know more products of our company, please click here
https://www.bcstgroup.com/

Saturday, May 16, 2020

JC-3000S Wall Installed Ultrasonic Flow Meter


JC-3000S ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation.
JC-3000S transit-time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method where the sound transverses the pipe twice, or W-method where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method depends on pipe and liquid characteristics. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the transit time that it takes for sound to travel between the two transducers. The difference in the transit time measured is directly and exactly related to the velocity of the liquid in the pipe, show as follows: 
Where
θ is the include angle to the flow direction
M is the travel times of the ultrasonic beam
D is the pipe diameter
Tup is the time for the beam from upstream transducer to the downstream one
Tdown is the time for the beam from downstream transducer to the upstream one
ΔT=Tup –Tdown
Optional Transducers
Model
Description
Measuring range
Temperature
Accuracy
Small size transducer 
TS-1
Magnetic
DN15-100mm
-40~90℃
±1%
Medium size transducer

TM-1
Magnetic
DN50-1000mm
-40~90℃
±1%
Large size transducer 

TL-1
Magnetic
DN300-6000mm
-40~90℃
±1%
High-temperature small size transducer 

THS-1

DN15-100mm
-40~160℃
±1%
High-temperature medium size transducer
THM-1

DN50-1000mm
-40~160℃
±1%
The wall-mounting flow meter can be applied to a wide range of pipe flow measurements. 
Applicable liquids include pure liquids as well as liquid with small quantity of tiny particles.
Examples are: 
Water (hot water, chilled water, city water, sea water, waste water, etc.);
Sewage with small particle content;
Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);
Chemicals (alcohol, acids, etc.);
Plant effluent;
Beverage, liquid food;
 Ultra-pure liquids;
 Solvents and other liquids 
If you want to know more products of our company, please click here
https://www.bcstgroup.com/

Tuesday, May 12, 2020

Points to Be Noted in Electromagnetic Flowmeter Engineering Application

In the petrochemical, chemical, electric power, metallurgy, municipal, pharmaceutical and other industries, the technical difficulty and complexity of flow measurement are quite high. Research on flow measurement plays an important role in improving product quality, reducing business costs, and solving energy conservation and environmental protection. The electromagnetic flowmeter has the advantages of no resistance and no pressure loss, which can fully reduce the resistance in the pipeline and meet the requirements of energy saving and consumption reduction, so the electromagnetic flowmeter has been widely paid attention in the industry. However, although the electromagnetic flowmeter has the above advantages, and it is much better than most other types of flowmeters in reliability and stability, but in actual use, some problems will occur, the following magnetic flow meter factory will list the main points that need to be paid attention to in the application of electromagnetic flowmeter.
1. The transmitter should be installed at a position where the measurement tube can be filled with liquid at any time to prevent the illusion that the pointer is not at zero because of no liquid in the measurement tube. It is best to install it vertically to reduce the error caused by the liquid flowing through the bubble generated on the electrode. If placed horizontally, the two electrodes of the flowmeter must be kept on the same level, in order to prevent sediment or air on the top of the tube to insulate it.
KTSL-sleeve-control-valve.jpg
2. If necessary, the tube can be emptied. The built-in empty tube detection circuit will stop the accumulation and flow signal output.
3. For the fluid flowing in the anode-protected pipeline, the following points should be observed when installing the electromagnetic flowmeter: To make the fluid well grounded, a ground ring should be used; when the sensor is connected to the pipeline, there must be insulation between the flanges Insulation sleeves should also be used on the pads and screws.
4. When the electromagnetic flowmeter is installed on the grounded metal pipeline, the system potential balance is achieved through the grounding terminal on the electromagnetic flowmeter transmitter, that is, the copper core wire with a cross-sectional area of not less than 6mm2 is connected to the grounding terminal; When the electromagnetic flowmeter is installed on an ungrounded metal pipe, the two flanges are connected to the pipe flange through a copper core wire with a cross-sectional area of at least 6mm2 and are grounded. Connect the transmitter or sensor junction box to the ground terminal. Achieve system potential balance; when the electromagnetic flowmeter is installed on a plastic pipe or a pipeline with an insulating lining, the system potential balance is achieved through an additional ground ring, which is connected to the ground terminal through a copper core wire with a cross-sectional area of at least 6 mm2.

Wednesday, October 30, 2019

Insertion Magnetic Flowmeter with differential welded nipple and ball valve

Insertion  Magnetic Flowmeter with differential welded nipple and ball valve   can be used for differential size .