Showroom

Showroom
Showroom

Monday, August 3, 2020

Integral v-cone flow transmitter

Integral v-cone flow transmitter

 

V-cone flowmeter is widely used in petroleum, chemical industry, natural gas, mining and metallurgy, steel, electric power, water, water supply and drainage, paper making, sugar processing, pharmaceutical, brewing, beverage, textile, printing, dyeing, chemical fiber, environmental protection and municipal engineering industry measurement.

Because of the unique structure of V-cone flowmeter, fluid in the pipe doesn’t sharply contract, the change of fluid pressure is stable, and differential pressure signal is more stable, to ensure accurate measurement of flow, especially small flow.

At the same time, because of suspension of axis and tapered body structure, when fluid close to V cone, pipe center velocity slows while velocity around pipe wall speeds. High speed fluid directly washes inner cone throttling element and pipe wall, automatically realize cleaning, to avoid adhesion and accumulation of smudgy medium. It is applicable for liquid containing gas, gas containing water and gas or liquid containing solid. It has a unique advantage in measurement of coke oven gas, blast furnace gas, natural gas, liquefied petroleum gas, high-viscosity crude oil and smudgy.  

BCST V-cone flowmeter is widely used in petroleum, chemical industry, natural gas, mining and metallurgy, steel, electric power, water, water supply and drainage, paper making, sugar processing, pharmaceutical, brewing, beverage, textile, printing, dyeing, chemical fiber, environmental protection and municipal engineering industry measurement.

If you want to know more detailed information about this product, you can click the link below:

https://www.bcstgroup.com/product-integral-v-cone-flow-transmitter.html

Technical Parameter

Adopt National standard: GB/T2624-1993, SY / T6143-2004, International standard ISO5167

Pipe size: DN15 – DN3000

Basic Error: ±0.5%, ±1.5%, ±2.5%

Repeatability: ±0.1%

Working pressure: 2.5 MPa, 4.0MPa, 6.3 MPa, 10.0 MPa, 16.0 MPa, 26.0 MPa, 42.0 MPa

Medium temperature: < 550 ℃ 

Medium: Liquid, gas (including natural gas) or steam

Turndown: 10:1

Requirements to straight tube section: upstream 0-3D, downstream 0-1D

Power supply: 1) external: 24V DC  2) Internal (built-in battery): 3.6V DC

Display: 8-digit LCD display of flow rate, totalizer, flux pressure, flux temperature & troubleshot code.

Output signal: 1) 4-20mA DC flow signal

               2) Fit output signal of HRT protocol

               3) No output signal for battery powered flow meter  

Explosion proof: Intrinsically safe type IbIICT5

Enclosure: IP65 

BCST V-cone flowmeter Model Selection

Nominal Diameter

L (mm)

C

Nominal Diameter

L (mm)

C

DN15

150

M12 ×1.25

DN250

650

M20 ×1.5

DN20

150

M12 ×1.25

DN300

700

M20 ×1.5

DN25

150

M12 ×1.25

DN350

900

M20 ×1.5

DN32

165

M12 ×1.25

DN400

1050

M20 ×1.5

DN40

200

M12 ×1.25

DN450

1150

M20 ×1.5

DN50

250

M20 ×1.5

DN500

1260

M20 ×1.5

DN65

275

M20 ×1.5

DN600

1380

M20 ×1.5

DN80

300

M20 ×1.5

DN700

1500

M20 ×1.5

DN100

350

M20 ×1.5

DN800

1600

M20 ×1.5

DN125

400

M20 ×1.5

DN900

1750

M20 ×1.5

DN150

450

M20 ×1.5

DN1000

1850

M20 ×1.5

DN175

500

M20 ×1.5

DN1200

2000

M20 ×1.5

DN200

550

M20 ×1.5

DN1400

2200

M20 ×1.5

DN225

600

M20 ×1.5

DN1600

2500

M20 ×1.5

If you want to know more products of our company, please click here

Sunday, August 2, 2020

Points to Be Noted in Electromagnetic Flowmeter Engineering Application 3

12. Installation location. The electromagnetic flowmeter can be installed vertically and horizontally, but it is recommended to install vertically and the measured fluid flows from bottom to top. It can also be installed horizontally, but the two electrodes should be on the same level. When installing horizontally, ensure that the measuring tube is filled with liquid at all times. When the main pipeline is a vertical pipeline, under normal circumstances, the water flow is required to be bottom-up, try not to top-down. The latter is likely to cause relatively large flow fluctuations. In addition to the full pipe installation, this is also very important, followed by the distance of the straight pipe before and after. Choose a place that is convenient for maintenance and activities. The flowmeter should be installed at the rear end of the pump, never on the suction side: the valve should be installed on the downstream side of the flow.

13. Because the electromagnetic flowmeter measures a weak electric potential, it is necessary to eliminate all external interference to accurately measure, so good grounding is a necessary condition to ensure the stable operation of the electromagnetic flowmeter. Generally, grounding is achieved through the grounding ring or the reference electrode in the sensor and the grounding connection of the piping system.

Electromagnetic Flowmeter

14. The installation location of the flowmeter should be far away from all magnetic sources (such as high-power motors, transformers, etc.).

15. Like other flowmeters, electromagnetic flowmeters also have a protection level, usually the integrated protection level is IP65, and the split type is IP68 (for the sensor). If the customer has requirements for the installation environment of the instrument, the installation location is in an underground shady well. Or some other damp places, it is recommended that customers choose split type. In order to avoid damage caused by wrong selection.

16. Electromagnetic flowmeter can measure corrosive liquids, but the customer should provide other measurement media properties at the beginning of ordering to avoid errors in electrode selection during selection, which leads to the sensor being scrapped in the later use process, bringing inconvenience and economy to the customer on the loss.

17. Although the electromagnetic flowmeter is relatively reliable, it will not be damaged under normal circumstances, but due to its principle, the sensor electrode surface has been in contact with the liquid for a long time, and the electrode surface is more likely to be contaminated. Therefore, under normal circumstances, the electromagnetic flowmeter is recommended to be removed and cleaned once a year and a year and a half to ensure the measurement accuracy of the whole flowmeter. Any instrumentation requires "maintenance", and electromagnetic flowmeters are no exception.

The above information is provided by magnetic flow meter factory.

You can also find parts 2 and part 1 in our previous articles.

Saturday, August 1, 2020

JCLC Oval Gear Flowmeter with Pulse

JCLC Oval Gear Flowmeter with Pulse

Oval gear meters are instruments used for the continuous and intermittent measurement and control of the pipe liquid flow, which are typical of positive displacement meter, feature large flow range, low pressure loss, large viscosity range, easy installation, high accuracy and can measure high temperature, high viscosity liquids with easy calibration.

JC-LC oval gear meters are fitted with on-site pointer indication and roller integration device which can indicate the liquid flow and intermittent flow passing through the pipeline. For the different liquids (acid, alkali, salt, organic solution etc.), the meters can be made of different materials (cast iron, cast steel, stainless steel etc.). The meters are widely used for the flow measurement in the field of petroleum, chemical, chemical fiber, traffic, food industries and commerce, medical and sanitary departments.

 BCST Flowmeter with Pulse Operation Principle

Oval gear meter is generally comprised of a flow transducer and a counter mechanism. The main part of the transducer is a measuring chamber which consists of a pair of oval wheels and a sealing coupling. The counter mechanism contains speed reduction gears, adjusting device, counter, and pulse transmitter etc.

In the measuring chamber, a pair of oval wheels and cover plate make a crescent shape cavity which is used as a measuring unit. The oval wheels are rotated by the pressure difference in the inlet and outlet of the meter and drive the inlet liquid through the cavity to the outlet, each revolution of the oval wheels displaces fluid four time the volume of the cavity, the total revolutions of the oval wheels and the revolution rate will be transferred to the mechanical counter, and the total liquid volume and instantaneous flow will be known by the pointer display and the roller integration. The attached signal generator converts the rotary axial angular shift to the pulse signal and then transmits it to the electrical indicator for remote integrated flow and instantaneous flow indication and control.

Technical Parameter for BCST Oval Gear Flowmeter

1. Materials of main parts and the nominal operating pressure

JCLC-A

Cast steel

Cast iron

Stainless steel

Bronze(with oil) or rolling bearing

1.6

JCLC-E

Cast steel

Cast iron、Stainless steel

Under DN50 6.3

DN80-100  4.0

DN150-200  2.5

JCLC-Q

Cast iron

Cast iron

Alloy aluminum, engineering material

graphite

1.6

JCLC-B、C

Stainless steel

Stainless steel

Stainless steel

graphite

1.6、2.5

JCLC-L

Cast

aluminum

Cast iron,

Stainless steel

Alloy

aluminum, engineering material

Bronze(with oil)、graphite、rolling bearing

1.6

Notes:1. 0Cr18Ni12Mo2Ti for type JCLC-C; 0Cr18Ni9Ti for type JCLC-B

2. Flange is convex under 2.5MPa ,and roughness at 6.3 MPa;and both of the above at 4.0 MPa。

 

2. Accuracy        class 0.5, class 0.2 (normal operating temperature -10℃~+60℃)  

3. Measured media temp. (environment temperature -41℃~+50℃)

JCLC-A、B、C: -20℃~+60℃; 60℃~200℃(with high temp. radiator installed)

JCLC-Q、L: -20℃~+60℃;

4. Explosion-proof mark: ExiaⅡCT5, dⅡBT4

If you want to know more products of our company, please click here

https://www.bcstgroup.com/