ZJHY Pneumatic small flow control valve

 

  



ZJHY Pneumatic small flow control valve

Pneumatic small flow control valve product description

ZJHY pneumatic small flow control valve is a product developed independently by our company for small flow conditions. It consists of a pneumatic diaphragm actuator and a small flow control valve body. The multi-spring actuator has a low height, light weight, and simple equipment. Pneumatic small flow control valve features small size, light weight, high performance, precise control for small flow rates, etc. When adjusting unclean media, the problem of blocking jams should be taken care of with regard to the problem of small throttling clearance. Pneumatic small flow control valve is particularly suitable for the main flow adjustment of liquids, steam and other media.

BCST small flow control valve body Parameters

Nominal diameter(DN)

G3/8"、1/2"、G3/4"、G1"

Valve seat diameter(dn)

1.5

2

3

4

5

6

7

8

9

10

11

12

15

Rated flow coefficient KV

0.025

0.05

0.08

0.12

0.20

0.32

0.50

0.80

1.00

1.40

1.55

1.85

2.23

Allowable pressure 
difference(MPa)

≤Nominal pressure

Nominal pressure(MPa)

1.6、2.5、4.0、6.4、10.0、16.0、25.0、32.0

With actuator type

ZHA/B-11

Rated route(mm)

8

10

12

Valve cover form

standard type(-17~+250℃)、High temperature type(+250~+450℃)、Low temperature type(-40~-196℃)、Bellows sealed type(-40~+350℃)

Capping form

Bolt compression type

Seal packing

V type PTFE packing、V type flexible graphite filler

fValve body material

stainless steel(CF8、CF8M、CF3、CF3M、 Biphase stainless steel2520)

 

BCST pneumatic small flow control valve Valve trim parameters

Valve core form

single seat Plunger type

Flow characteristics

Linear, equal percentage

valve core material

stainless steel (304、316、316L)

 

Actuator parameters

Configure Actuator 
Category

ZHA/B Multi-spring film actuator

Actuator model

ZHA/B-11

Effective area(cm2)

200

route (mm)

10、16

Spring range(KPa)

20~100(standard)、20-60、60-100、40-200、80-240

Diaphragm material

Nitrile rubber clip nylon cloth, ethylene propylene rubber clip nylon cloth

Air supply pressure

140~400KPa

Air interface

RC1/4"

Ambient temperature

-30~+70℃

equipped with 
accessories

Locator, air filter pressure reducer, position valve, route switch, valve positioner, handwheel mechanism, etc.

Form of action

Air-to-close (B)—Valve open (FO) when deaeration; Air-opening (K)—Valve off (FC) when deaeration

 If you want to know more detailed information about this product, you can click the link below:

https://www.bcstgroup.com/product-pneumatic-small-flow-control-valve.html

Sunday, August 9, 2020

Electromagnetic Flowmeter Installation and Maintenance

 Instrument maintenance personnel should improve their ability to judge instrument failures and be more familiar with instrument principles, structure, and performance characteristics. However, there are more than 60 flow meters involved in chemical production. How can instrument workers maintain and control the normal operation of meters? Regarding the installation and fault maintenance of flow meters, this article sorts out one of the commonly used flow meters for you.

Electromagnetic flowmeter is an instrument for measuring conductive liquid made according to Faraday's law of electromagnetic induction. The electromagnetic flowmeter is composed of three parts: sensor, converter, and cable connection line, all of which are indispensable. If the cable connection is short, install it in the flowmeter housing.

Electromagnetic flowmeter has a series of excellent characteristics, which can solve the problems that other flowmeters are not easy to use, such as the measurement of dirty flow and corrosive flow.

Advantage:

The measuring channel is a smooth straight pipe that will not be blocked. It is suitable for measuring liquid-solid two-phase fluids containing solid particles, such as pulp, mud, sewage, etc.;

No pressure loss caused by flow detection, and good energy saving effect;

The measured volume flow is actually not significantly affected by changes in fluid density, viscosity, temperature, pressure and conductivity;

Large flow range and wide caliber range;

Corrosive fluids can be used.

Electromagnetic Flowmeter

Disadvantages:

Cannot measure liquids with very low conductivity, such as petroleum products;

Cannot measure gas, steam and liquid with large bubbles;

Cannot be used for higher temperatures.

Installation requirements of electromagnetic flowmeter

Choice of installation site

In order to make the electromagnetic flowmeter work stable and reliable, the following requirements should be paid attention to when choosing the installation location:

1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields (large motors, large transformers, etc.) to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.

2. It should be installed in a dry and ventilated place as much as possible, avoiding sun and rain, the ambient temperature should be -20~+60℃, and the relative humidity should be less than 85%.

3. There should be ample space around the flowmeter for easy installation and maintenance.

The above information is provided by flow instrument manufacturer.


Wednesday, August 5, 2020

Electromagnetic Flowmeter Installation and Maintenance

Instrument maintenance personnel should improve their ability to judge instrument failures and be more familiar with instrument principles, structure, and performance characteristics. However, there are more than 60 flow meters involved in chemical production. How can instrument workers maintain and control the normal operation of meters? Regarding the installation and fault maintenance of flow meters, this article sorts out one of the commonly used flow meters for you.

Electromagnetic flowmeter is an instrument for measuring conductive liquid made according to Faraday's law of electromagnetic induction. The electromagnetic flowmeter is composed of three parts: sensor, converter, and cable connection line, all of which are indispensable. If the cable connection is short, install it in the flowmeter housing.

Electromagnetic flowmeter has a series of excellent characteristics, which can solve the problems that other flowmeters are not easy to use, such as the measurement of dirty flow and corrosive flow.

Advantage:

The measuring channel is a smooth straight pipe that will not be blocked. It is suitable for measuring liquid-solid two-phase fluids containing solid particles, such as pulp, mud, sewage, etc.;

No pressure loss caused by flow detection, and good energy saving effect;

The measured volume flow is actually not significantly affected by changes in fluid density, viscosity, temperature, pressure and conductivity;

Large flow range and wide caliber range;

Corrosive fluids can be used.

Electromagnetic Flowmeter

Disadvantages:

Cannot measure liquids with very low conductivity, such as petroleum products;

Cannot measure gas, steam and liquid with large bubbles;

Cannot be used for higher temperatures.

Installation requirements of electromagnetic flowmeter

Choice of installation site

In order to make the electromagnetic flowmeter work stable and reliable, the following requirements should be paid attention to when choosing the installation location:

1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields (large motors, large transformers, etc.) to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.

2. It should be installed in a dry and ventilated place as much as possible, avoiding sun and rain, the ambient temperature should be -20~+60℃, and the relative humidity should be less than 85%.

3. There should be ample space around the flowmeter for easy installation and maintenance.

The above information is provided by flow instrument manufacturer.


Monday, August 3, 2020

Integral v-cone flow transmitter

Integral v-cone flow transmitter

 

V-cone flowmeter is widely used in petroleum, chemical industry, natural gas, mining and metallurgy, steel, electric power, water, water supply and drainage, paper making, sugar processing, pharmaceutical, brewing, beverage, textile, printing, dyeing, chemical fiber, environmental protection and municipal engineering industry measurement.

Because of the unique structure of V-cone flowmeter, fluid in the pipe doesn’t sharply contract, the change of fluid pressure is stable, and differential pressure signal is more stable, to ensure accurate measurement of flow, especially small flow.

At the same time, because of suspension of axis and tapered body structure, when fluid close to V cone, pipe center velocity slows while velocity around pipe wall speeds. High speed fluid directly washes inner cone throttling element and pipe wall, automatically realize cleaning, to avoid adhesion and accumulation of smudgy medium. It is applicable for liquid containing gas, gas containing water and gas or liquid containing solid. It has a unique advantage in measurement of coke oven gas, blast furnace gas, natural gas, liquefied petroleum gas, high-viscosity crude oil and smudgy.  

BCST V-cone flowmeter is widely used in petroleum, chemical industry, natural gas, mining and metallurgy, steel, electric power, water, water supply and drainage, paper making, sugar processing, pharmaceutical, brewing, beverage, textile, printing, dyeing, chemical fiber, environmental protection and municipal engineering industry measurement.

If you want to know more detailed information about this product, you can click the link below:

https://www.bcstgroup.com/product-integral-v-cone-flow-transmitter.html

Technical Parameter

Adopt National standard: GB/T2624-1993, SY / T6143-2004, International standard ISO5167

Pipe size: DN15 – DN3000

Basic Error: ±0.5%, ±1.5%, ±2.5%

Repeatability: ±0.1%

Working pressure: 2.5 MPa, 4.0MPa, 6.3 MPa, 10.0 MPa, 16.0 MPa, 26.0 MPa, 42.0 MPa

Medium temperature: < 550 ℃ 

Medium: Liquid, gas (including natural gas) or steam

Turndown: 10:1

Requirements to straight tube section: upstream 0-3D, downstream 0-1D

Power supply: 1) external: 24V DC  2) Internal (built-in battery): 3.6V DC

Display: 8-digit LCD display of flow rate, totalizer, flux pressure, flux temperature & troubleshot code.

Output signal: 1) 4-20mA DC flow signal

               2) Fit output signal of HRT protocol

               3) No output signal for battery powered flow meter  

Explosion proof: Intrinsically safe type IbIICT5

Enclosure: IP65 

BCST V-cone flowmeter Model Selection

Nominal Diameter

L (mm)

C

Nominal Diameter

L (mm)

C

DN15

150

M12 ×1.25

DN250

650

M20 ×1.5

DN20

150

M12 ×1.25

DN300

700

M20 ×1.5

DN25

150

M12 ×1.25

DN350

900

M20 ×1.5

DN32

165

M12 ×1.25

DN400

1050

M20 ×1.5

DN40

200

M12 ×1.25

DN450

1150

M20 ×1.5

DN50

250

M20 ×1.5

DN500

1260

M20 ×1.5

DN65

275

M20 ×1.5

DN600

1380

M20 ×1.5

DN80

300

M20 ×1.5

DN700

1500

M20 ×1.5

DN100

350

M20 ×1.5

DN800

1600

M20 ×1.5

DN125

400

M20 ×1.5

DN900

1750

M20 ×1.5

DN150

450

M20 ×1.5

DN1000

1850

M20 ×1.5

DN175

500

M20 ×1.5

DN1200

2000

M20 ×1.5

DN200

550

M20 ×1.5

DN1400

2200

M20 ×1.5

DN225

600

M20 ×1.5

DN1600

2500

M20 ×1.5

If you want to know more products of our company, please click here