Electric High Temperature Steam Globe Control Valve

 


ZWZP Electric High Temperature Steam Globe Control Valve

Electric High Temperature Steam Globe Control Valve

This high temperature control valve is composed of an electric actuator and a high precision low flow resistance regulating valve body. The electric high-temperature steam globe control valve has the advantages of tight closing, compact structure, light weight and convenient maintenance.The BCST electric high temperature control valve is equipped with a 3810 series (or PSL series) electric actuator and a small precision regulating valve body. It accepts a standard signal of 4-20 mA or 1-5 V·DC to convert the current signal into a corresponding linear displacement.The electric high temperature control valve adopts a balanced valve plug structure, which is widely used in the occasions where the flow rate is large, the temperature is high, and the leakage amount is not strict.

Technical Parameters of BCST High Temperature Steam Globe Control Valve:

DN(mm)

20

25

32

40

50

65

80

100

125

150

200

250

300

Seat Dia.(mm)

20

25

32

40

50

65

80

100

125

150

200

250

300

Rated Kv

Single-seated

6.9

11

17.6

27.5

44

69

110

176

275

440

630

875

1250

Cage Guided

6.3

10

16

25

40

63

100

155

250

370

580

900

1300

Allowed Pressure Difference

(MPa)

Single-seated

3.8

3.2

3

2

1.8

1.5

1.4

1

0,7

0.6

0.5

0.3

0.1

Cage Guided

6.4

6.4

5.2

5.2

4.6

4.6

3.7

3.7

3.5

3.1

3.1

2.6

2.2

PN(MPa)

1.6、2.5、4.0、6.4、10.0

Rated Travel(mm)

16

25

40

60

100

Bonnet Type

high temperature type(+250~+450℃)

Seal Packing

PTFE, flexible graphite

Plug Type

Single seated,cage guided

Flow Characteristic

Equal percentage,linear

Actuator Type

3810 series electric actuator,PSL series electric actuator

Actuator Parameter

Power voltage:220V,input singal:4-20mA or 1-5V·DC,output signal:4-20mA·DC

Protection level:IP65,Explosion-proof:ExdⅡBT4(ExdⅡBT6 customized),manual function: handle

Ambient temperature:-25~+70℃,ambient humidity:≤95%

If you want to know more products of our company, please click here

https://www.bcstgroup.com/







Wednesday, August 12, 2020

ZJHY Pneumatic small flow control valve

 

  



ZJHY Pneumatic small flow control valve

Pneumatic small flow control valve product description

ZJHY pneumatic small flow control valve is a product developed independently by our company for small flow conditions. It consists of a pneumatic diaphragm actuator and a small flow control valve body. The multi-spring actuator has a low height, light weight, and simple equipment. Pneumatic small flow control valve features small size, light weight, high performance, precise control for small flow rates, etc. When adjusting unclean media, the problem of blocking jams should be taken care of with regard to the problem of small throttling clearance. Pneumatic small flow control valve is particularly suitable for the main flow adjustment of liquids, steam and other media.

BCST small flow control valve body Parameters

Nominal diameter(DN)

G3/8"、1/2"、G3/4"、G1"

Valve seat diameter(dn)

1.5

2

3

4

5

6

7

8

9

10

11

12

15

Rated flow coefficient KV

0.025

0.05

0.08

0.12

0.20

0.32

0.50

0.80

1.00

1.40

1.55

1.85

2.23

Allowable pressure 
difference(MPa)

≤Nominal pressure

Nominal pressure(MPa)

1.6、2.5、4.0、6.4、10.0、16.0、25.0、32.0

With actuator type

ZHA/B-11

Rated route(mm)

8

10

12

Valve cover form

standard type(-17~+250℃)、High temperature type(+250~+450℃)、Low temperature type(-40~-196℃)、Bellows sealed type(-40~+350℃)

Capping form

Bolt compression type

Seal packing

V type PTFE packing、V type flexible graphite filler

fValve body material

stainless steel(CF8、CF8M、CF3、CF3M、 Biphase stainless steel2520)

 

BCST pneumatic small flow control valve Valve trim parameters

Valve core form

single seat Plunger type

Flow characteristics

Linear, equal percentage

valve core material

stainless steel (304、316、316L)

 

Actuator parameters

Configure Actuator 
Category

ZHA/B Multi-spring film actuator

Actuator model

ZHA/B-11

Effective area(cm2)

200

route (mm)

10、16

Spring range(KPa)

20~100(standard)、20-60、60-100、40-200、80-240

Diaphragm material

Nitrile rubber clip nylon cloth, ethylene propylene rubber clip nylon cloth

Air supply pressure

140~400KPa

Air interface

RC1/4"

Ambient temperature

-30~+70℃

equipped with 
accessories

Locator, air filter pressure reducer, position valve, route switch, valve positioner, handwheel mechanism, etc.

Form of action

Air-to-close (B)—Valve open (FO) when deaeration; Air-opening (K)—Valve off (FC) when deaeration

 If you want to know more detailed information about this product, you can click the link below:

https://www.bcstgroup.com/product-pneumatic-small-flow-control-valve.html

Sunday, August 9, 2020

Electromagnetic Flowmeter Installation and Maintenance

 Instrument maintenance personnel should improve their ability to judge instrument failures and be more familiar with instrument principles, structure, and performance characteristics. However, there are more than 60 flow meters involved in chemical production. How can instrument workers maintain and control the normal operation of meters? Regarding the installation and fault maintenance of flow meters, this article sorts out one of the commonly used flow meters for you.

Electromagnetic flowmeter is an instrument for measuring conductive liquid made according to Faraday's law of electromagnetic induction. The electromagnetic flowmeter is composed of three parts: sensor, converter, and cable connection line, all of which are indispensable. If the cable connection is short, install it in the flowmeter housing.

Electromagnetic flowmeter has a series of excellent characteristics, which can solve the problems that other flowmeters are not easy to use, such as the measurement of dirty flow and corrosive flow.

Advantage:

The measuring channel is a smooth straight pipe that will not be blocked. It is suitable for measuring liquid-solid two-phase fluids containing solid particles, such as pulp, mud, sewage, etc.;

No pressure loss caused by flow detection, and good energy saving effect;

The measured volume flow is actually not significantly affected by changes in fluid density, viscosity, temperature, pressure and conductivity;

Large flow range and wide caliber range;

Corrosive fluids can be used.

Electromagnetic Flowmeter

Disadvantages:

Cannot measure liquids with very low conductivity, such as petroleum products;

Cannot measure gas, steam and liquid with large bubbles;

Cannot be used for higher temperatures.

Installation requirements of electromagnetic flowmeter

Choice of installation site

In order to make the electromagnetic flowmeter work stable and reliable, the following requirements should be paid attention to when choosing the installation location:

1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields (large motors, large transformers, etc.) to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.

2. It should be installed in a dry and ventilated place as much as possible, avoiding sun and rain, the ambient temperature should be -20~+60℃, and the relative humidity should be less than 85%.

3. There should be ample space around the flowmeter for easy installation and maintenance.

The above information is provided by flow instrument manufacturer.


Wednesday, August 5, 2020

Electromagnetic Flowmeter Installation and Maintenance

Instrument maintenance personnel should improve their ability to judge instrument failures and be more familiar with instrument principles, structure, and performance characteristics. However, there are more than 60 flow meters involved in chemical production. How can instrument workers maintain and control the normal operation of meters? Regarding the installation and fault maintenance of flow meters, this article sorts out one of the commonly used flow meters for you.

Electromagnetic flowmeter is an instrument for measuring conductive liquid made according to Faraday's law of electromagnetic induction. The electromagnetic flowmeter is composed of three parts: sensor, converter, and cable connection line, all of which are indispensable. If the cable connection is short, install it in the flowmeter housing.

Electromagnetic flowmeter has a series of excellent characteristics, which can solve the problems that other flowmeters are not easy to use, such as the measurement of dirty flow and corrosive flow.

Advantage:

The measuring channel is a smooth straight pipe that will not be blocked. It is suitable for measuring liquid-solid two-phase fluids containing solid particles, such as pulp, mud, sewage, etc.;

No pressure loss caused by flow detection, and good energy saving effect;

The measured volume flow is actually not significantly affected by changes in fluid density, viscosity, temperature, pressure and conductivity;

Large flow range and wide caliber range;

Corrosive fluids can be used.

Electromagnetic Flowmeter

Disadvantages:

Cannot measure liquids with very low conductivity, such as petroleum products;

Cannot measure gas, steam and liquid with large bubbles;

Cannot be used for higher temperatures.

Installation requirements of electromagnetic flowmeter

Choice of installation site

In order to make the electromagnetic flowmeter work stable and reliable, the following requirements should be paid attention to when choosing the installation location:

1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields (large motors, large transformers, etc.) to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.

2. It should be installed in a dry and ventilated place as much as possible, avoiding sun and rain, the ambient temperature should be -20~+60℃, and the relative humidity should be less than 85%.

3. There should be ample space around the flowmeter for easy installation and maintenance.

The above information is provided by flow instrument manufacturer.